AI and Neurological Rare & Neuroimmune Diseases ── Parkinson's ── 2026-11-27

Parkinson's disease and parkinsonism: treatment, trials and AI
- Abstract
Speech motor dysfunction affects approximately 90% of patients with Parkinson's disease (PD), but multimodal neuroimaging models for prediction of this impairment remain limited. We developed MCTA-FusNet, an interpretable deep learning framework that integrates structural, resting-state functional, and diffusion MRI to predict speech motor dysfunction in PD. The model incorporates modality-specific encoders and a hierarchical triple-attention fusion mechanism to capture channel-, spatial-, and modality-level interactions. Using cross-domain transfer learning, MCTA-FusNet was first pretrained on the PPMI dataset (n = 400) to predict motor symptom severity (UPDRS-III) and then fine-tuned on the FAH-SYSU dataset (n = 81) to predict speech motor dysfunction, indexed by vocal response magnitude (VRMag) to pitch perturbations. MCTA-FusNet outperformed all unimodal and multimodal models with transfer learning, achieving the lowest mean absolute error (1.388 ± 0.62) and highest correlation between predicted and observed VRMag (r = 0.731, p < 0.001). Interpretability analyses identified the superior temporal gyrus, primary motor cortex, premotor cortex, and supplementary motor area as key predictors, with greater coherence and phase synchrony between auditory and premotor regions significantly correlated with exaggerated VRMag. These findings establish a multimodal neuroimaging deep learning model for predicting and explaining speech motor dysfunction in PD, offering a novel framework with potential for symptom-specific monitoring and therapeutic intervention.
Journal IF-equivalent: 12.9 (OpenAlex 2-year mean citedness, value as of 2026-11-25, retrieved 2026-11-26; not the official Clarivate IF)Reference: Zhao S, Dai G, Wang M, Zhu X, Li Y, Tan M, et al. Multimodal neuroimaging fusion with interpretable deep learning for speech motor dysfunction in Parkinson’s disease. PLOS Digit Health. 2026 Nov 24;5(11):e0001864. doi:10.1371/journal.pdig.0001864.Checked: Abstract only - Abstract
Freezing of gait (FoG) is a disabling, episodic gait disturbance in Parkinson’s disease (PD) and a leading cause of falls. Wearable inertial sensors combined with machine learning promise continuous, objective FoG monitoring, but most published models are validated only within a single dataset, so their transportability to new patients, devices and protocols is unknown. We benchmarked four detectors—Random Forest, XGBoost, a one-dimensional convolutional neural network (1D-CNN) and a CNN-LSTM—on the Daphnet FoG dataset (10 people with PD, 64 Hz) using leave-one-subject-out cross-validation (LOSO-CV) with all standardisation parameters fitted on training folds only, and then performed a cross-dataset external validation on an independent 100-subject lower-back accelerometer cohort (TLVMC; 62 subjects recorded in the laboratory, “tdcsfog”, and 38 recorded at home under a structured FoG-provoking protocol, “defog”) with different hardware, placement and sampling rate. To make internal and external estimates directly comparable, all models were trained on the trunk sensor only; uncertainty was quantified by subject-level bootstrap and by repeated training seeds. Under LOSO-CV the 1D-CNN reached a subject-mean AUROC of 0.84 (95% CI 0.77–0.91) and detected 146 of 180 annotated freezing episodes (81%), with substantially higher sensitivity than the feature-based baselines (0.68 vs. 0.34–0.52). Without any adaptation to the target data, the same model reached a pooled-window AUROC of 0.80 (0.68–0.86) in the external laboratory cohort and 0.61 (0.55–0.68) in the home-protocol cohort; the participant-level AUROC, the estimand reported internally, was 0.66 (0.61–0.72) and 0.59 (0.54–0.63), respectively. The feature-based baselines transferred less well (pooled AUROC 0.52–0.70). Reverse-transfer experiments showed that laboratory and home recordings from the same source transfer well to each other (AUROC 0.78–0.92), suggesting that the change of data source (device, placement, population and annotation) contributed more to the transfer loss than the laboratory-versus-home setting. Discrimination transferred across datasets but calibration did not: at the default threshold external sensitivity was low, whereas a threshold calibrated on the training data alone, combined with causal median filtering, raised window-level sensitivity in the laboratory cohort to 0.27–0.42 at specificity ≥ 0.95; causal median filtering reduced false alarms three- to seven-fold but also reduced episode-level sensitivity and lengthened detection latency. Integrated Gradients attributed 58–61% of the deep models’ decision evidence to the 3–8 Hz “freeze” band in every held-out subject, convergent with SHAP analysis of the XGBoost comparator and with established FoG physiology. These results provide a leakage-controlled, uncertainty-quantified estimate of how wearable FoG detectors generalise, and suggest that cross-source transfer and calibration remain major obstacles to deployment; clinical utility was not evaluated.
Journal IF-equivalent: 6.3 (OpenAlex 2-year mean citedness, value as of 2026-11-09, retrieved 2026-11-10; not the official Clarivate IF)Reference: Cheng Q, Zhang G, Wang F, Zhang J. Explainable deep learning for freezing-of-gait detection from wearable accelerometry: a leakage-controlled cross-dataset external validation study. Sci Rep. 2026 Nov 23 [Epub ahead of print]. doi:10.1038/s41598-026-81436-7.Checked: Abstract only